Showing results: 1306 - 1320 of 2454 items found.
-
El-Mul Technologies
El-Mul’s proprietary technologies enable unique solutions for compact BSE energy spectrometers. El-Mul’s unique high-resistivity coating stands at the forefront of our energy filtering detection platform. This unique coating is key for high voltage holding over short distances in vacuum.
-
SP1000 Series -
Twintex Electronics Co., Ltd
The SP1000 series linear DC power supplies are made with 1 output channel, rated power from 15W to 180W, with 3 digits or 4 digis LED display. With linear copper transformer, the relay converts the secondary output voltage with high efficiency.
-
IMS-2001 -
Shanghai Jiuzhi Electric Co., Ltd.
IMS-2001 is made for high voltage testing laboratory operating environment, serious consider EMC hardware design, the system especially considering the impulse test characteristics used in most polluted areas, and it meet the standard such as IEC61083, IEC60060, IEEE1122, GB/T16896.1, IEC61000 and etc.
-
325 SVD -
Standard Electric Works Co., Ltd
● Compact, easy to wear and convenient in use● Designed for indoor and outdoor use● Water-proof design. (IP65)● Equipped with self-testing functions● Able to sense all kinds of AC High Voltage System● Low power consumption● CE Certifiedright LED visual indication
-
40-419-002 -
Pickering Interfaces Ltd.
The 40-419-002 is a 48-channel digital I/O module suitable for operating external devices, such as power, RF and high voltage relays, solenoids and lamps. It can also be used for interfacing with external logic such as a programmable instrument with a BCD interface depending upon the module’s driving capabilities.
-
40-419-003 -
Pickering Interfaces Ltd.
The 40-419-003 is a 32-channel digital I/O module suitable for operating external devices, such as power, RF and high voltage relays, solenoids and lamps. It can also be used for interfacing with external logic such as a programmable instrument with a BCD interface depending upon the module’s driving capabilities.
-
40-419-004 -
Pickering Interfaces Ltd.
The 40-419-004 is a 16-channel digital I/O module suitable for operating external devices, such as power, RF and high voltage relays, solenoids and lamps. It can also be used for interfacing with external logic such as a programmable instrument with a BCD interface depending upon the module’s driving capabilities.
-
40-419-001 -
Pickering Interfaces Ltd.
The 40-419-001 is a 64-channel digital I/O module suitable for operating external devices, such as power, RF and high voltage relays, solenoids and lamps. It can also be used for interfacing with external logic such as a programmable instrument with a BCD interface depending upon the module’s driving capabilities.
-
Communications & Power Industries
The CPI TMD high-voltage power supplies offer many features desirable for modern radar and electronic warfare applications: high efficiency, ultra-low voltage ripple (low noise), high inverter frequencies, ultra-low pulse-to-pulse jitter, low throughput delay and high power density. The units are lightweight and compact with excellent thermal management, and the high-voltage sections are encapsulated with an oil-free, silicone-based compound. This provides excellent protection in harsh environments while also enabling easy maintenance.
-
CAEN S.p.A.
- From 12 to 24 independently controllable High Voltage channels- 8 kV maximum output voltage- Maximum Current 1 mA- Either Radiall Multipin or SHV connectors- Available with either positive or negative polarity- Up to 500 pA/50 pA current set / monitor resolution- Up to 100 mV/10 mV voltage set / monitor resolution- Very Low ripple, down to < 5 mV- 3 different channel grounding - Common Ground (AGxxxx) - Common Floating Return (Axxxx) - Individual Floating (A1534 only)- Independently programmable for each channel: - Output voltage - Current limit - Ramp up/down (1 ÷ 500 V/sec) - TRIP parameter- Current generator operation in overcurrent condition- Specific design for Germanium detectors (A15x0H only)
-
Extech EX355 -
Extech Instruments Corporation
The EX355 is a professional DMM loaded with advanced features and functions. Low Impedance (LoZ) mode eliminates false readings caused by ghost voltages. Low Pass Filter (LPF)attenuates high frequencies to reduce noise for accurate readings. True RMS provides accurate readings when measuring distorted or noisy waveforms. Built-in Non-Contact AC Voltage Detector quickly checks for the presence of AC Voltage before testing. Features a 6000 count LCD display, data hold, min-max, relative mode, capacitance zero, auto power off, continuity and diode test. This meter will measure AC/DC voltage to 600 V and AC/DC current to 10 amps. Complete with test leads, general purpose bead wire temperature probe, manual and two AA batteries.
-
HBM-S1-B -
High Power Pulse Instruments GmbH
*±6 kV Human-Body-Model (HBM) 2-pin tester according ANSI/ESDA/JEDEC JS-001 standard with C = 100 pF, R = 1.5 kΩ discharge network*True HBM: the classical discharge network of the HBM-S1-A according the standard ensures compliant waveforms for all load conditions*Optionally available upgrade for all HPPI TLP-3010C, 4010C, 8010A, and 8010C hardware systems and software (upgrade on request)*Suppression of trailing pulses*Integrated 10 kΩ charge removal resistor*Integrated DUT voltage and DUT current sensor for real time voltage and current monitoring*Integrated DC test DUT switchIntegrated hardware 50 Ω trigger output for high speed digital oscilloscopesIntegrated overvoltage protection of voltage sense and DC test interfaces for oscilloscope and SMU protection during high voltage HBM testing*Fast and efficient HBM measurements including transient waveform data management using the HPPI TLP software*Compact size 145 mm x 82.5 mm x 44 mm
-
UI2002C -
Lisun Electronics Inc.
UI2002C is designed according to the latest update in IEC 61347-2-3 about the test requirements for local rectifying effects on tubes. It imitates the condition when tube is under local rectifying status and tests the abnormal protection function of ballast by adopting fluorescent lamp asymmetry pulse test method with 3 windows for displaying rectified voltage, rectified current, and rectified power. It is easy for operation and with high test accuracy. • Measure lamp voltage, lamp current , average and total power of lamp. • Lamp voltage range: 10~300V • Lamp current range: 10mA~1.0A • Lamp power range: 0.5~300W • Tolerance is 5%
-
M9111A -
Keysight Technologies
The M9111A is a 1-slot, 2-quadrant PXIe module that provides stable, glitch-free sourcing and sinking, and high accuracy measurements. It offers high-throughput and measurement quality for design validation and production test of RF power amplifiers. With industry-leading output stability under extreme, dynamic load conditions and unmatched transient performance to dramatically reduce voltage droop due to pulse loading, the M9111A SMU speeds test time. The high-speed M9111A can change its output voltage, stabilize that voltage, and accurately measure current from Amps down to micro-Amps all in less than 1 ms so that you can move on to the next test as quickly as possible.
-
285 HD -
Standard Electric Works Co., Ltd
● Three different ranges of identification of AC voltage: 285-A HD : 3~7 kV 285-B HD : 6.6~11 kV 285-C HD : 10~22 kV● The LCD will "flash continuously" for high voltage testing.● Physical contact with electrical conductors is not nec- essary when testing for live wires.● The 285 HD senses the radiated field that surrounds live conductors.● Radiated field strength increases with voltage and decreases quickly with distance.● Large LCD.● Continuous monitoring.● Easy to install.● No batteries required.● Weight : Approx. 80g.● Meets EN 61326-1 EN 55011 EN 61000-4-2 EN 61000-4-3